Optimisers
Power optimiser P404-4RM4MRM SolarEdge
Manufacturer: SolarEdge
INDEX: P404-4RM4MRM
The SolarEdge P404 power optimiser has an excellent efficiency of 99.5% and has been specially designed for use with SolarEdge inverters. This product has a unique solution that prevents the problem of module mismatch or partial shading.
Separate monitoring for each module greatly facilitates system management. The SolarEdge P404 has a function to reduce the voltage of each module—during installation or in case of fire.
Distinguishing features of the product:
 Up to 25% more energy
 Up to 25% more energy
 Excellent efficiency (99.5%)
Excellent efficiency (99.5%)
 A unique solution that prevents the problem of module mismatch or partial shading
A unique solution that prevents the problem of module mismatch or partial shading
 Maximum use of space thanks to a flexible system design
Maximum use of space thanks to a flexible system design
 Quick mounting with one screw
Quick mounting with one screw
 Separate monitoring for each module greatly facilitates system management
Separate monitoring for each module greatly facilitates system management
 Voltage reduction of each module—during installation or in case of fire
Voltage reduction of each module—during installation or in case of fire
Cable length:
- input cables 0.16 m
- output cables 1.2 m
| Type: | Optymalizator | 
|---|---|
| Supported number of PV modules: | 1 | 
| Weight [kg]: | 0.78 | 
| Dimensions [mm]: | 89 x 42.5 x 129 | 
| Maximum short-circuit current per MPPT [A]: | 11 | 
|---|---|
| Number of optimisers per chain: | - | 
| Power [W]: | 405 | 
| Max. voltage [V]: | 80 | 
| Min. MPPT voltage [V]: | 12.5 | 
| Max. MPPT voltage [V]: | 80 | 
| Euro efficiency [%]: | 98.8 | 
|---|---|
| Max. efficiency [%]: | 99.5 | 
| Chain length - HD-WAVE and single phase inverter / number of optimisers and PV modules: | 6 - 25 | 
|---|---|
| Chain length - three-phase inverter / number of optimisers and PV modules: | 14 - 50 | 
| Maximum Power per String - inverter HD-WAVE [W]: | 5700 | 
| Maximum Power per String - inverter three phase [W]: | 11250 | 
| Maximum chain power - single phase inverter [W]: | 5250 | 
| Minimum String Length - inverter three phase SE 3 kW / number of optimizers and PV modules: | 13 | 
 
                                                                         
                                                                                                             
                                                                                                            